Buy or sell Anything Over Chat

2000W Solar Grid Tie Inverter with Limiter Single Phase String Inverter DC100-500V AC160-300V

Sale!
2000W Solar Grid Tie Inverter with Limiter Single Phase String Inverter DC100-500V AC160-300V

2000W Solar Grid Tie Inverter with Limiter Single Phase String Inverter DC100-500V AC160-300V

2,517.703,187.29

no Limiter Sensorwith Limiter Sensor
100-500V
160-300V
China
Clear
Qty:
Compare
SKU: 4001155680855 Category:

Description

2000W Solar Power Grid Tie Inverter with Limiter Function

String Inverter
DC 100V-500V input Voltage.
AC 160V-300V Single Phase output Voltage .

Wi- Fi function Yes (need wifi port)
Limiter Function selectable .

Ha42dfc2c54584b08ab5e124844e6b70e5 - 2000W Solar Grid Tie Inverter with Limiter Single Phase String Inverter DC100-500V AC160-300VH66234451fd524f7e81a06824036b839c9 - 2000W Solar Grid Tie Inverter with Limiter Single Phase String Inverter DC100-500V AC160-300V

Leading Features:

1. Max Efficiency of 97.5% and wide input range.
2. Single MPPT design with accurate MPPT algorithm. 3. Intelligent cooling, IP65 protection.
4. Compact and light design for easy Installation.
5. Transformerless GT topology.
6. RS485, WiFi Interface.
7. Numerous protection functions.
8. Optional build in Anti-Overflow function.
9. 7 years standard warranty, 25 years lifespan design.

Had198150290b4b0498ddab4d0f8fb9c31 - 2000W Solar Grid Tie Inverter with Limiter Single Phase String Inverter DC100-500V AC160-300V

Technical Specification

Model : SUN-2K-G

Energy source : Grid-connected PV

Input Side
Max.DC Power(kW) : 2.6KW
Max.DC Input Voltage(V) : 500V
Start-up DC Input Voltage(V) : 120V
MPPT Operating Range(V) : 100-500V

Max.DC Input Current(A) : 10A
Number of MPP/Number of Strings : 1/1

Output Side

Rated Output Power(kW) : 2KW
Max. Active Power(kW) : 2.2KW
Rated AC Grid Voltage(V) : 220V

AC Grid Voltage Range(V) : 160-270V

Rated Grid Frequency(Hz) : 50/60Hz (Optional)

Operating Phase : Single phase

Rated AC Grid Output Current(A) : 8.7A
Max.AC Output Current(A) : 9.6A
Output Power Factor : >0.99

Grid Current THD : <3%
DC Injection Current(mA) : <0.5%

Grid Frequency Range (Hz) : 47-52Hz or 57-62Hz(Optional)

Efficiency

Max. Efficiency : 97.3%
Euro Efficiency : 97.1%
MPPT Efficiency : >99%

Protection

DC Reverse-Polarity Protection : Yes
AC Short Circuit Protection : Yes
AC Output Overcurrent Protection : Yes
Output Overvoltage Protection : Yes
Insulation Resistance Protection : Yes
Ground Fault Monitoring : Yes
Surge Protection : Yes
Islanding Protection : Yes
Temperature Protection : Yes
Integrated DC Switch : Optional

General Data

Size(mm) : 330W*348H*130D

Weight(kg/lb) : 7kg / 22.5lb

Topology : Transformerless

Internal Consumption : <2W(Night)
Running Temperature : -25-60°C
Ingress Protection : IP65
Noise Emission(Typical : <30 dB
Cooling Concept : Natural convection
Max. Operating Altitude Without Derating : 2000m
Designed Lifetime : >20 years
Grid Connection Standard :

EN50438,IEC61727,VDE4105 ,

NB/T32004(CQC),IEC62109-1-2

Operating Surroundings Humidity : 0-100%

Stafty EMC /Standard :

IEC62109-1/-2,NB/T 32004,

EN61000-6-1,EN61000-6-3

Features :

DC Connection

MC-4 mateable

AC Connection

IP65 rated plug

Display

3.5TFT

Interface

RS485/RS232

H0907a104c93e41cb91cb1e07fec5e2242 - 2000W Solar Grid Tie Inverter with Limiter Single Phase String Inverter DC100-500V AC160-300VHe78b1286416647ebbe5f9fcb86bef4ee1 - 2000W Solar Grid Tie Inverter with Limiter Single Phase String Inverter DC100-500V AC160-300V

Limiter function wiring diagram

When you are reading this, we believe that you have completed the connection according
to the requirements of chapter 5, if you has been running your inverter at this time, and
you want to use the limiter function, please turn off AC and DC switch of the inverter, and wait for 5 minutes until the inverter completely discharged. Then connect the current
sensor to the inverter limiter interface.Make sure they are reliably connected, and the
current sensor should clamp to the live wire of the incoming line.In order to make it easier for you to use the built-in limiter function of the inverter, we have specifically given the wiring diagram,as shown in Picture 7.1, the red lines connected to the utility grid said wire (L), blue line shows the zero line (N), yellow green line shows the ground wire (PE). We recommend installing a AC switch between the inverter outlet and the utility grid, the specs of the AC switch is determined according to the load capacity. The AC switch we recommend to connect to the inverter output can refer to Table 5.1.If there is no integrated DC switch inside the inverter you purchased, were commend you to connect the DC switch. The voltage and current of the switch depends on the PV array you access.

Photovoltaic Grid-connected System

H61fe8113af984ab5b71916520e66874cU - 2000W Solar Grid Tie Inverter with Limiter Single Phase String Inverter DC100-500V AC160-300VH932156ac89f64eeda5851d1b99a41afeG - 2000W Solar Grid Tie Inverter with Limiter Single Phase String Inverter DC100-500V AC160-300V

Photovoltaic Grid-connected System

H61fe8113af984ab5b71916520e66874cU - 2000W Solar Grid Tie Inverter with Limiter Single Phase String Inverter DC100-500V AC160-300VH932156ac89f64eeda5851d1b99a41afeG - 2000W Solar Grid Tie Inverter with Limiter Single Phase String Inverter DC100-500V AC160-300V

Additional information

is_customized

Yes

Output Current

Max 10A

Output Frequency

50Hz / 60Hz

Output Power

2000W

Output Type

single

Weight

7kg

Size

330*347.5*127mm

Is Smart Device

Yes

Model Number

SUN-2K-G

Reviews

There are no reviews yet.

Be the first to review “2000W Solar Grid Tie Inverter with Limiter Single Phase String Inverter DC100-500V AC160-300V”