Buy or sell Anything Over Chat

1PCS CT1-25 16A 20A 25A 32A 2P 2NO 2P 4P 4NO CT1-63 32A 40A 63A 230v 50/60HZ Din Rail Household AC Contactor

Sale!
1PCS CT1-25 16A 20A 25A 32A 2P 2NO 2P 4P 4NO CT1-63 32A 40A 63A 230v 50/60HZ Din Rail Household AC Contactor

1PCS CT1-25 16A 20A 25A 32A 2P 2NO 2P 4P 4NO CT1-63 32A 40A 63A 230v 50/60HZ Din Rail Household AC Contactor

118.98174.34

CT1-25-2P-16ACT1-25-2P-20ACT1-25-2P-25ACT1-25-4P-16ACT1-25-4P-20ACT1-25-4P-25ACT1-63-2P-32ACT1-63-2P-40ACT1-63-2P-63ACT1-63-4P-32ACT1-63-4P-40ACT1-63-4P-63A
Clear
Qty:
Compare
SKU: 10000382153138 Category:

Description

Super quality excellent 2P 16A/20A/25A 220V/230V 50/60HZ din rail household ac contactor.
This 2P 230V 50/60HZ 2NO, 1NO 1NC, 2NC you can choose.

CT1 house hold AC contactor is mainly designed for AC 50Hz or 60Hz circuits with 230V . Rated operating voltage in AC-7a usage ,rated operating voltage up to 230V, rated operating current up to 25A, Rated operating voltage in AC-7b usage , rated current to 10A. Using in breaking capacity below 6kA circuit. For distance connect or break the circuit.

Application: for home, apartment, hotel, automatic cut off or connect the power.

Normal working and installation conditions:

1. Ambient temperature:-5°C to +40°C,the average temperature no more than +35°C in 24 hours.

2. Altitude:no more than 2000m.

3. Atmospheric conditions: the relative humidity of the installation place should be no more than 50% when the maximum temperature is +40°C:if under a lower temperature,a higher relative humidity is allowed. The monthly average minimum temperature in the wettest month should not exceed +25°C and the monthly average maximum relative humidity of this month no more than 90%.Besides,the dew on the surface of products caused by temperature change should be taken into consideration.

4. Class of pollution: class 2.

5. Installation condition: class II.

Application instruction

1. Check whether the contactor agrees with the scope of application and the working condition before installation

2. During the process of installing pull down the motion stopping component and put the contactor on the safe orbit then push up the motion-stopping component to fix the contactor on the safe orbit avoid loosening and dropping pull down the motion-stopping component if you want to remove the contactor.

Caution

a).Make sure the correct mode of connection

b).Screw down the binding screw during the connection

Main tech data
Contactor model TOCT1-16 2NO TOCT1-20 2NO TOCT1-25 2NO
Rated isolating voltage (Ui) V 500 500 500
Rated operating voltage (Ue) V 230 230 230
Thermal continuous current (Ith) A 16 20 25
Rated working current (Ie) AC-7a A 16 20 25
AC-7b A 9 9 10
Rated working power (Pe) AC-7a kW 4 4 5.4
AC-7b A kW 1.2 1.2 1.4
Operating times 10 thousand Hd9dd477015b046339acd4cc21e130072d - 1PCS CT1-25 16A 20A 25A 32A 2P 2NO 2P 4P 4NO CT1-63 32A 40A 63A 230v 50/60HZ Din Rail Household AC Contactor3
Operating frequency AC-7a turns/Hour 1200
AC-7b turns/Hour 30
Connect and break capability AC-7a A 1.5Ie
AC-7b A 8Ie
Withstand current (ICW) 10S A 8Ie/AC-7b
Connecting wiring 1 wire mm2 1–2.5 1–2.5 1–4
2 wire mm2 1–2.5 1–2.5 1–4
Coil
Control power voltage (Us) AC V 220/230
Coil power W 1.4

Hf3b13397c2844ff294377a0ceaefbd173 - 1PCS CT1-25 16A 20A 25A 32A 2P 2NO 2P 4P 4NO CT1-63 32A 40A 63A 230v 50/60HZ Din Rail Household AC ContactorH51fc7acbc4e640db81d61a12b5b47e54y - 1PCS CT1-25 16A 20A 25A 32A 2P 2NO 2P 4P 4NO CT1-63 32A 40A 63A 230v 50/60HZ Din Rail Household AC ContactorH51fc7acbc4e640db81d61a12b5b47e54y - 1PCS CT1-25 16A 20A 25A 32A 2P 2NO 2P 4P 4NO CT1-63 32A 40A 63A 230v 50/60HZ Din Rail Household AC ContactorH26eb56403dd34a98b3aa8c35be3256938 - 1PCS CT1-25 16A 20A 25A 32A 2P 2NO 2P 4P 4NO CT1-63 32A 40A 63A 230v 50/60HZ Din Rail Household AC Contactor

Hfd1d5a62d06b483a98be338e4e320b76g - 1PCS CT1-25 16A 20A 25A 32A 2P 2NO 2P 4P 4NO CT1-63 32A 40A 63A 230v 50/60HZ Din Rail Household AC ContactorHe7e51d4aaf274c10b4cdc846cd6e1ce3G - 1PCS CT1-25 16A 20A 25A 32A 2P 2NO 2P 4P 4NO CT1-63 32A 40A 63A 230v 50/60HZ Din Rail Household AC Contactor
H4a618cf75d0c4016b0c5ddc0ed28c437K - 1PCS CT1-25 16A 20A 25A 32A 2P 2NO 2P 4P 4NO CT1-63 32A 40A 63A 230v 50/60HZ Din Rail Household AC ContactorHb7f44016477140d7a05f4c1642e4f093S - 1PCS CT1-25 16A 20A 25A 32A 2P 2NO 2P 4P 4NO CT1-63 32A 40A 63A 230v 50/60HZ Din Rail Household AC ContactorHf0b99a5554724966aaf95fdcf794781fQ - 1PCS CT1-25 16A 20A 25A 32A 2P 2NO 2P 4P 4NO CT1-63 32A 40A 63A 230v 50/60HZ Din Rail Household AC ContactorHadf96476ac8a42a38d324ed337bf7e78h - 1PCS CT1-25 16A 20A 25A 32A 2P 2NO 2P 4P 4NO CT1-63 32A 40A 63A 230v 50/60HZ Din Rail Household AC Contactor

Additional information

Electricity Type

AC

Phase

2

Number of Pole

2

is_customized

Yes

Main Circuit Rating Voltage

220V

Model Number

CT1-25-2P

Main Circuit Rating Current

25A

Reviews

There are no reviews yet.

Be the first to review “1PCS CT1-25 16A 20A 25A 32A 2P 2NO 2P 4P 4NO CT1-63 32A 40A 63A 230v 50/60HZ Din Rail Household AC Contactor”

Your email address will not be published. Required fields are marked *

X